Non-Contact Thickness Measurement of Metal Foil—Capturing the Thickness of Moving Amorphous Foil

Source: Keyence•November 26, 2026 at 01:31 AM

Non-Contact Thickness Measurement of Metal Foil—Capturing the Thickness of Moving Amorphous Foil

Non-contact, inline measurement of the total thickness of metal foil and amorphous ribbon by sandwiching them (difference between upper and lower heads) with the CL-3000 Series confocal displacement sensor. Stable measurement is possible even for magnetic material foils that are glossy,…

Three Challenges That Arise When the Thickness of Metal Foil and Amorphous Ribbon Cannot Be Measured Correctly

Thickness variation in moving opaque, ultra-thin foil directly affects characteristics and yield rate. Conventional methods each have their own limitations on-site.

Thickness Variation Directly Affects Characteristics and Yield Rate

For amorphous ribbon and magnetic material foil, thickness affects magnetic and lamination characteristics. Variations can cause out-of-specification products and defects in subsequent processes. If not detected while moving, defects manifest after winding or in the final product, leading to raw material loss and complaints. Managing thickness over the entire length and for 100% of products is key to quality. Even a slight trend change in thickness can result in a large volume of defective products escaping, significantly impacting the yield rate and costs.

Opaque and Ultra-Thin, Making Conventional Methods Difficult to Use

Because metal foil is opaque, transmitted light and spectral interference are difficult to use. Additionally, reflection conditions are severe for ultra-thin, glossy surfaces, making simple reflection methods unstable. Surface waviness and flutter while moving also cause errors, reducing measurement reliability. A non-contact method that can stably capture the total thickness of moving foil is required. Measuring with unstable reflection compromises quality control, leading to the rejection of good products or overlooking defects.

Contact and Radiation Methods Have Limitations On-Site

Contact micrometers require stopping the line, which can cause scratches and deformation on soft foil. Beta-ray and X-ray thickness gauges involve radiation management and installation constraints, creating hurdles for introduction and operation. A non-contact method is needed that can measure thickness for 100% of products without stopping the line or using radiation. Overlooking local thickness changes will cause defects to manifest in subsequent processes or final products, leading to rework and complaints.

Key Points for Measuring the Thickness of Moving Foil

From unwinding to recording, the total thickness of moving opaque, ultra-thin foil is managed non-contact and for 100% of products using the difference between the upper and lower sensor heads.

  • 1 Unwinding and Conveying – Measurement 1. The unwound foil is passed between the upper and lower sensor heads while being conveyed. Align the optical axes of the upper and lower heads using a dedicated jig to prepare for sandwich measurement.
  • 2 Total Thickness Measurement via Upper/Lower Difference – Measurement 2. The distances to the upper and lower surfaces of the foil are measured by the upper and lower sensor heads using the multi-color confocal method, and the total thickness of the moving foil is calculated from the difference. All sensor heads are measured synchronously with a single controller.
  • 3 Measurement Resistant to Gloss and Flutter – Measurement 3. Thanks to the multi-color confocal method and excellent angle characteristics, returned light is stably captured and measured even on glossy surfaces, tilted surfaces, or fluttering moving foil.
  • 4 Recording and 100% Inspection Management – Measurement 4. Thickness is recorded over the entire length to detect variations and local thickness changes. Quality is managed for 100% of products without stopping the line.

Comparison of Thickness Measurement Methods for Metal Foil and Amorphous Ribbon

Depending on the measurement method, there are significant differences in non-contact properties, suitability for opaque foil, 100% inspection management while moving, and the necessity of radiation.

Non-contact / Influence on foil

CL-3000 Series (Multi-color confocal, upper/lower dual-head sandwiching / non-contact)

○ Non-contact, no scratches

Contact micrometer

× Risk of scratches/deformation

Beta-ray/X-ray thickness gauge

○ Non-contact

Suitability for opaque/glossy foil

CL-3000 Series (Multi-color confocal, upper/lower dual-head sandwiching / non-contact)

○ Stable even on glossy surfaces with multi-color confocal

Contact micrometer

○ Suitable for any material

Beta-ray/X-ray thickness gauge

○ Suitable for any material

While moving / 100% inline

CL-3000 Series (Multi-color confocal, upper/lower dual-head sandwiching / non-contact)

◎ 100% inspection without stopping the line

Contact micrometer

× Requires stopping / sample inspection

Beta-ray/X-ray thickness gauge

△ Depends on configuration/installation

Radiation control / installation restrictions

CL-3000 Series (Multi-color confocal, upper/lower dual-head sandwiching / non-contact)

○ No radiation required

Contact micrometer

○ No radiation required

Beta-ray/X-ray thickness gauge

× Radiation control / installation restrictions

Role (strength)

CL-3000 Series (Multi-color confocal, upper/lower dual-head sandwiching / non-contact)

Total thickness of moving, opaque, and ultra-thin foil (100% inspection)

Contact micrometer

Thickness of stationary foil

Beta-ray/X-ray thickness gauge

Thickness regardless of material

Why Choose the CL-3000 Series

The CL-3000 Series uses a multi-color confocal method to stably capture returned light even from glossy surfaces or fluttering moving foil. It performs non-contact measurement of the total thickness of opaque, ultra-thin foil using the difference between the upper and lower heads, whose optical axes are aligned with a dedicated jig. This enables 100% inspection without stopping the line, and because it does not use radiation, it avoids scratches and line stops associated with contact methods, as well as the installation constraints of beta-ray/X-ray methods.

CL-3000 Series Supporting Thickness Measurement of Metal Foil and Amorphous Ribbon

A multi-color confocal displacement sensor. It measures the total thickness of moving foil without contact using the difference between the upper and lower heads.

Supporting Thickness Measurement of Metal Foil and Amorphous Ribbon - CL-3000 Series

Confocal Displacement Sensor

A blue laser is shone onto a phosphor that emits red and green light simultaneously to generate multi-color light, which is then coaxially projected with different focal lengths for each wavelength. With the "multi-color confocal method," only the light of the wavelength that is most in focus passes through a pinhole and is received by the Quad CMOS, allowing high-accuracy distance measurement with a single sensor head regardless of the material. Because the optical axis is coaxial, returned light is stably captured even from glossy or tilted surfaces. In thickness measurement of metal foil and amorphous ribbon, the total thickness of the moving, opaque, and ultra-thin foil is calculated non-contact from the difference between the upper and lower heads positioned to sandwich the foil. The dedicated jig and the optical axis alignment function of the PC software suppress installation errors in sandwich measurement, and the excellent angle characteristics ensure stable measurement of even fluttering moving foil. A single controller can synchronously measure all heads, managing the thickness over the entire length and for 100% of the products without stopping the line. Since it does not use radiation, installation and operation constraints are minimized, making it useful for inline thickness management on manufacturing and processing lines for amorphous ribbon and magnetic material foil.

View Catalog

Click here for product information on the CL-3000 Series

Get Detailed Documentation on the CL-3000 Series

You can download a free catalog summarizing specifications, system configuration, and application examples.

View Catalog

Inquiries about thickness measurement of metal foil and amorphous ribbon

Application Examples of Thickness Measurement of Metal Foil and Amorphous Ribbon

It is used for thickness measurement of various moving, opaque, and ultra-thin foils, such as amorphous ribbon and magnetic material foil.

Foil Thickness Measurement

The thickness of foil made by bonding dissimilar metals is measured via an adjustable fixture that pinches the foil with upper and lower sensor heads. It suppresses the influence of errors caused by optical axis misalignment, enabling high-accuracy measurement.

Foil Flutter Inspection

Inspects foil flutter before coating. With the CL-3000 Series, which has excellent angle characteristics, measurement can be performed without problems even if the foil flutters, improving coating quality.

Electrode Coating Thickness Measurement

Measures the thickness after electrode coating without contact. It measures all materials with high accuracy, such as glossy foil and rough coated surfaces.

Frequently Asked Questions About Thickness Measurement of Metal Foil and Amorphous Ribbon (CL-3000 Series)

Yes, it can. Because the CL-3000 Series determines the total thickness from the difference between the upper and lower heads sandwiching the foil, it can measure the thickness of even opaque, ultra-thin metal foil where transmitted light cannot be used, in a non-contact manner while moving.

Yes, it is stable. Because of the multi-color confocal method, returned light is stably captured even from glossy or tilted surfaces, and measurement is performed with excellent angle characteristics while suppressing the influence of fluttering while moving.

With the dedicated jig and the optical axis alignment function of the PC software, the optical axes can be easily aligned by performing rough and fine adjustments with a reference target in between. This minimizes installation errors and enables high-accuracy sandwich thickness measurement.

Because the CL-3000 Series does not use radiation, radiation management and installation restrictions can be minimized. The total thickness of all products can be measured non-contact without stopping the line, lowering the hurdles for operation.

  • Confocal Displacement Sensor CL-3000 series

Confocal Displacement Sensor

CL-3000 series

← All articles

What this article says

More in Industrial & Industry 4.0

All →
Controlling Can Dimensions in the Can Manufacturing Process: Outer Can Dimensions, Grooves Inside the Can, and Gaps With the Lid
Keyence

Controlling Can Dimensions in the Can Manufacturing Process: Outer Can Dimensions, Grooves Inside the Can, and Gaps With the Lid

3D Measurement of Flatness and Warpage: 100% Inspection of Traveling Steel Sheets With Line Profiles
Keyence

3D Measurement of Flatness and Warpage: 100% Inspection of Traveling Steel Sheets With Line Profiles

3D Coplanarity Measurement: 100% Surface Judgment of Terminal Group Heights
Keyence

3D Coplanarity Measurement: 100% Surface Judgment of Terminal Group Heights

3D Measurement of PCB Warpage: 100% Surface Inspection of Mounted Component Heights
Keyence

3D Measurement of PCB Warpage: 100% Surface Inspection of Mounted Component Heights

Measuring the Outer Diameter and Ovality of Steel Pipes and Tubes: Continuous Inline Measurement With Simultaneous 2-Axis and Environmentally Resistant Design
Keyence

Measuring the Outer Diameter and Ovality of Steel Pipes and Tubes: Continuous Inline Measurement With Simultaneous 2-Axis and Environmentally Resistant Design

Biodiesel Plant Improves Process Control, Increases Output | Rockwell Automation | US
Rockwell Automation

Biodiesel Plant Improves Process Control, Increases Output | Rockwell Automation | US

More from Keyence

Controlling Can Dimensions in the Can Manufacturing Process: Outer Can Dimensions, Grooves Inside the Can, and Gaps With the Lid
Keyence

Controlling Can Dimensions in the Can Manufacturing Process: Outer Can Dimensions, Grooves Inside the Can, and Gaps With the Lid

3D Measurement of Flatness and Warpage: 100% Inspection of Traveling Steel Sheets With Line Profiles
Keyence

3D Measurement of Flatness and Warpage: 100% Inspection of Traveling Steel Sheets With Line Profiles

3D Coplanarity Measurement: 100% Surface Judgment of Terminal Group Heights
Keyence

3D Coplanarity Measurement: 100% Surface Judgment of Terminal Group Heights

3D Measurement of PCB Warpage: 100% Surface Inspection of Mounted Component Heights
Keyence

3D Measurement of PCB Warpage: 100% Surface Inspection of Mounted Component Heights

Measuring the Outer Diameter and Ovality of Steel Pipes and Tubes: Continuous Inline Measurement With Simultaneous 2-Axis and Environmentally Resistant Design
Keyence

Measuring the Outer Diameter and Ovality of Steel Pipes and Tubes: Continuous Inline Measurement With Simultaneous 2-Axis and Environmentally Resistant Design

Non-Contact Measurement of Groove Depth and Width: Numerical Inspection of Groove Dimensions With 3D Shape Measurement
Keyence

Non-Contact Measurement of Groove Depth and Width: Numerical Inspection of Groove Dimensions With 3D Shape Measurement