The LS-9000 Series optical micrometer provides non-contact, simultaneous 2-axis measurement of the outer diameter and ovality of steel pipes and tubes. With its structure containing no moving parts and an environmentally resistant design featuring an IP67 rating and air purge, it ensures stable measurement even on pipe manufacturing lines with dust and coolant.
View Catalog
Inquiries about Outer Diameter and Ovality Measurement of Steel Pipes and Tubes
Three Reasons Why Outer Diameter and Ovality Measurement of Steel Pipes and Tubes Is Difficult
Variations in outer diameter and ovality directly affect strength, pressure resistance, and standard compliance. Choosing the wrong measurement method leads to defects and losses.
Variations in Outer Diameter and Ovality Directly Affect Quality
If the outer diameter or cross-sectional ovality of steel pipes and tubes varies, it affects strength, pressure resistance, and standard compliance, leading to poor pipe connections and pressure test failures. In pipe manufacturing and rolling, slight variations in conditions appear as outer diameter variations or cross-sectional ovalization, requiring management over the entire length. Without stable dimensional control, it leads to a decrease in yield rate and a lack of traceability.
Limitations of Contact and Single-Axis Laser Methods on the Factory Floor
Contact methods depend on the skill level of the operator, cannot keep up with fast-moving steel pipes, and also cause wear. Single-axis measurement using laser scanning methods can only measure the outer diameter in one direction, making it difficult to grasp the cross-sectional ovality in a single pass. There is a demand for a method that can keep up with production speeds and simultaneously measure outer diameter and ovality in a non-contact manner.
Dust, Coolant, and Vibration Hinder Stable Measurement
Pipe manufacturing lines are harsh environments with a lot of cutting fluid (coolant), dust, and travel vibration. Transmission-type measuring instruments require more frequent cleaning due to dirty lenses, which becomes a cost factor, and methods with moving parts carry a risk of failure. An environmentally resistant design is required that considers long-term, stable use in various environments.
Pipe Manufacturing and Rolling Processes and Outer Diameter/Ovality Measurement Points
By understanding the outer diameter and ovality in each process from pipe manufacturing to shipping inspection, defects can be detected early.
- 1 Pipe manufacturing and rolling – Measurement (1). Outer diameter and ovality are measured, and the results are fed back to manufacturing conditions such as rolls/mandrels to converge to target dimensions.
- 2 Straightening – Measurement (2). Checks ovality and outer diameter after straightening to detect over-straightening and cross-sectional deviation (ovalization).
- 3 Cutting – Measurement (3). Makes a final judgment on outer diameter and ovality during cutting to prevent non-conforming materials from flowing into subsequent processes.
- 4 Shipping inspection – Measurement (4). Obtains the outer diameter and ovality profile over the entire length to ensure standard compliance and traceability.
Comparison of Outer Diameter and Ovality Measurement Methods for Steel Pipes and Tubes
Depending on the measurement method, there are significant differences in non-contact capability, simultaneous measurement of outer diameter and ovality, environmental resistance, and inline adaptability.
Non-contact measurement
LS-9000 Series (Green LED, non-contact)
○ Non-contact
Laser scanning method (single-axis, outer diameter only)
○ Non-contact
Contact method (calipers, gauges, etc.)
× Contact/pressing (with measuring force)
Simultaneous measurement of outer diameter and ovality
LS-9000 Series (Green LED, non-contact)
○ Simultaneous outer diameter and ovality measurement with X-Y 2-axis
Laser scanning method (single-axis, outer diameter only)
× Outer diameter in 1 direction only (ovality not possible)
Contact method (calipers, gauges, etc.)
× Difficult to obtain simultaneously
Environmental resistance (dust, coolant, shock)
LS-9000 Series (Green LED, non-contact)
○ IP67 compliant, air purge unit, no moving parts, shock-resistant structure
Laser scanning method (single-axis, outer diameter only)
× Vulnerable to scanning mechanism deterioration and measurement lens dirt
Contact method (calipers, gauges, etc.)
× Wear, uneven contact
Cleaning and maintenance load
LS-9000 Series (Green LED, non-contact)
○ No moving parts to reduce failuresAir purge unit reduces cleaning frequency
Laser scanning method (single-axis, outer diameter only)
△ Maintenance of scanning mechanism is required
Contact method (calipers, gauges, etc.)
△ Calibration and wear management are required
High-speed inline 100% inspection
LS-9000 Series (Green LED, non-contact)
○ 100% inspection even during travel at 16,000 times per second
Laser scanning method (single-axis, outer diameter only)
△ Depending on the model
Contact method (calipers, gauges, etc.)
× Mainly stopped/sample inspection
Why Choose the LS-9000 Series
The LS-9000 Series uses X-Y 2-axis optical measurement to simultaneously acquire the outer diameter and ovality of steel pipes and tubes in a single pass without contact. The structure with no moving parts using a high-brightness green LED and proprietary optics reduces failures and the frequency of lens cleaning compared to laser scanning methods. The IP67 structure and air purge unit prevent dirt on the front of the head, ensuring stable measurement even on pipe manufacturing lines with dust and coolant. Furthermore, the die-cast body and optical unit protection design absorb shock and temperature changes with the outer body to protect the internal optics (meets IEC 60068-2-27 shock resistance requirements). This enables inline 100% inspection in harsh environments while reducing maintenance man-hours.
LS-9000 Series for Outer Diameter and Ovality Measurement of Steel Pipes and Tubes
An optical micrometer that detects edges using transmitted green LED light. With 2-axis simultaneous measurement and an environmentally resistant design, it ensures stable measurement even on harsh pipe manufacturing lines.
For Outer Diameter and Ovality Measurement of Steel Pipes and Tubes — LS-9000 Series
High-speed optical micrometer
The outer diameter of steel pipes and tubes is measured without contact using an optical method that detects edges of transmitted green LED light with a CMOS sensor. The 2-axis models (LS-9030D/LS-9006D) simultaneously measure the outer diameter in the X and Y directions, allowing ovality to be evaluated from the difference. The structure with no moving parts, using a high-brightness green LED and proprietary optics, reduces failures and the frequency of lens cleaning. The IP67 structure and air purge unit prevent dirt on the front of the head, and the die-cast body absorbs shock and temperature changes to protect the internal optical unit (meets IEC 60068-2-27 shock resistance requirements). High-speed sampling of 16,000 times per second and tilt correction ensure stable 100% inspection of moving steel pipes. A single controller supports simultaneous measurement of up to 16 channels, and up to four large-diameter heads capable of measuring up to φ120 mm can be connected.
View Catalog
Click here for LS-9000 Series product information
Get Detailed Materials for the LS-9000 Series
You can download a free catalog summarizing specifications, system configuration, and application examples.
View Catalog
Inquiries regarding outer diameter and ovality measurement of steel pipes and tubes
Application Examples of Outer Diameter and Ovality Measurement of Steel Pipes and Tubes
The LS-9000 Series is used for outer diameter and ovality measurement in various steel pipe processes, such as pipe manufacturing and rolling.
Inline Outer Diameter and Ovality Measurement on Pipe Manufacturing Lines
Steel pipes flowing continuously are measured simultaneously on the X and Y axes to monitor the outer diameter and ovality for 100% inspection. High-speed sampling of 16,000 times per second enables reliable measurement despite vibration during travel and prevents missing local changes in outer diameter.
Outer Diameter Measurement of Large-Diameter Steel Pipes
By using two sensor heads, the outer diameter of large-diameter steel pipes, such as φ500 mm, which cannot be captured by a single head, can be measured. Non-contact 100% inspection is performed even for large-sized objects that are difficult to handle.
Stable Measurement in Dust and Coolant Environments (Environmentally Resistant Design)
The IP67 structure and air purge unit prevent dirt on the front of the head, and the structure with no moving parts reduces failures of moving parts and the frequency of lens cleaning. The die-cast body absorbs shock and temperature changes to protect the internal optics (shock resistance IEC 60068-2-27). Measurement can be performed without stopping even on pipe manufacturing lines with dust or coolant.
Frequently Asked Questions Regarding Outer Diameter and Ovality Measurement of Steel Pipes and Tubes
Yes, they can. The 2-axis models (LS-9030D/LS-9006D) simultaneously acquire the outer diameter in the X and Y directions, allowing ovality (ovality of the cross section) to be evaluated from the difference.
Yes, it can. The IP67 structure and air purge unit prevent dirt on the front of the head, and the structure with no moving parts reduces failures of moving parts, ensuring stable measurement even on harsh pipe manufacturing lines.
Yes, it can. Non-contact X-Y 2-axis measurement obtains the outer diameter and ovality in a single pass. Continuous measurement can be performed over the entire length without stopping the moving steel pipe.
Yes, it can. With high-speed sampling of 16,000 times per second and non-contact measurement, it supports continuous 100% inspection on pipe production lines.
Yes, it can. The tilt correction function handles vibration and tilt during operation, and the die-cast body and optical unit protection design absorb shock and temperature changes (meets IEC 60068-2-27 shock resistance requirements).
Yes, it can. Up to four large-diameter heads capable of measuring up to φ120 mm can be connected, and a single controller supports simultaneous measurement of up to 16 channels.
- High-speed optical micrometer LS-9000 series
High-speed optical micrometer
LS-9000 series