Measuring the Outer Diameter and Ovality of Steel Pipes and Tubes: Continuous Inline Measurement With Simultaneous 2-Axis and Environmentally Resistant Design

Source: Keyence•November 26, 2026 at 01:30 AM

Measuring the Outer Diameter and Ovality of Steel Pipes and Tubes: Continuous Inline Measurement With Simultaneous 2-Axis and Environmentally Resistant Design

The LS-9000 Series optical micrometer performs non-contact, simultaneous 2-axis measurement of the outer diameter and ovality of steel pipes and tubes. With an environmentally resistant design featuring a drive-less structure, IP67 rating, air purge, and shock resistance (IEC 60068-2-27), it…

The LS-9000 Series optical micrometer provides non-contact, simultaneous 2-axis measurement of the outer diameter and ovality of steel pipes and tubes. With its structure containing no moving parts and an environmentally resistant design featuring an IP67 rating and air purge, it ensures stable measurement even on pipe manufacturing lines with dust and coolant.

View Catalog

Inquiries about Outer Diameter and Ovality Measurement of Steel Pipes and Tubes

Three Reasons Why Outer Diameter and Ovality Measurement of Steel Pipes and Tubes Is Difficult

Variations in outer diameter and ovality directly affect strength, pressure resistance, and standard compliance. Choosing the wrong measurement method leads to defects and losses.

Variations in Outer Diameter and Ovality Directly Affect Quality

If the outer diameter or cross-sectional ovality of steel pipes and tubes varies, it affects strength, pressure resistance, and standard compliance, leading to poor pipe connections and pressure test failures. In pipe manufacturing and rolling, slight variations in conditions appear as outer diameter variations or cross-sectional ovalization, requiring management over the entire length. Without stable dimensional control, it leads to a decrease in yield rate and a lack of traceability.

Limitations of Contact and Single-Axis Laser Methods on the Factory Floor

Contact methods depend on the skill level of the operator, cannot keep up with fast-moving steel pipes, and also cause wear. Single-axis measurement using laser scanning methods can only measure the outer diameter in one direction, making it difficult to grasp the cross-sectional ovality in a single pass. There is a demand for a method that can keep up with production speeds and simultaneously measure outer diameter and ovality in a non-contact manner.

Dust, Coolant, and Vibration Hinder Stable Measurement

Pipe manufacturing lines are harsh environments with a lot of cutting fluid (coolant), dust, and travel vibration. Transmission-type measuring instruments require more frequent cleaning due to dirty lenses, which becomes a cost factor, and methods with moving parts carry a risk of failure. An environmentally resistant design is required that considers long-term, stable use in various environments.

Pipe Manufacturing and Rolling Processes and Outer Diameter/Ovality Measurement Points

By understanding the outer diameter and ovality in each process from pipe manufacturing to shipping inspection, defects can be detected early.

  • 1 Pipe manufacturing and rolling – Measurement (1). Outer diameter and ovality are measured, and the results are fed back to manufacturing conditions such as rolls/mandrels to converge to target dimensions.
  • 2 Straightening – Measurement (2). Checks ovality and outer diameter after straightening to detect over-straightening and cross-sectional deviation (ovalization).
  • 3 Cutting – Measurement (3). Makes a final judgment on outer diameter and ovality during cutting to prevent non-conforming materials from flowing into subsequent processes.
  • 4 Shipping inspection – Measurement (4). Obtains the outer diameter and ovality profile over the entire length to ensure standard compliance and traceability.

Comparison of Outer Diameter and Ovality Measurement Methods for Steel Pipes and Tubes

Depending on the measurement method, there are significant differences in non-contact capability, simultaneous measurement of outer diameter and ovality, environmental resistance, and inline adaptability.

Non-contact measurement

LS-9000 Series (Green LED, non-contact)

○ Non-contact

Laser scanning method (single-axis, outer diameter only)

○ Non-contact

Contact method (calipers, gauges, etc.)

× Contact/pressing (with measuring force)

Simultaneous measurement of outer diameter and ovality

LS-9000 Series (Green LED, non-contact)

○ Simultaneous outer diameter and ovality measurement with X-Y 2-axis

Laser scanning method (single-axis, outer diameter only)

× Outer diameter in 1 direction only (ovality not possible)

Contact method (calipers, gauges, etc.)

× Difficult to obtain simultaneously

Environmental resistance (dust, coolant, shock)

LS-9000 Series (Green LED, non-contact)

○ IP67 compliant, air purge unit, no moving parts, shock-resistant structure

Laser scanning method (single-axis, outer diameter only)

× Vulnerable to scanning mechanism deterioration and measurement lens dirt

Contact method (calipers, gauges, etc.)

× Wear, uneven contact

Cleaning and maintenance load

LS-9000 Series (Green LED, non-contact)

○ No moving parts to reduce failuresAir purge unit reduces cleaning frequency

Laser scanning method (single-axis, outer diameter only)

△ Maintenance of scanning mechanism is required

Contact method (calipers, gauges, etc.)

△ Calibration and wear management are required

High-speed inline 100% inspection

LS-9000 Series (Green LED, non-contact)

○ 100% inspection even during travel at 16,000 times per second

Laser scanning method (single-axis, outer diameter only)

△ Depending on the model

Contact method (calipers, gauges, etc.)

× Mainly stopped/sample inspection

Why Choose the LS-9000 Series

The LS-9000 Series uses X-Y 2-axis optical measurement to simultaneously acquire the outer diameter and ovality of steel pipes and tubes in a single pass without contact. The structure with no moving parts using a high-brightness green LED and proprietary optics reduces failures and the frequency of lens cleaning compared to laser scanning methods. The IP67 structure and air purge unit prevent dirt on the front of the head, ensuring stable measurement even on pipe manufacturing lines with dust and coolant. Furthermore, the die-cast body and optical unit protection design absorb shock and temperature changes with the outer body to protect the internal optics (meets IEC 60068-2-27 shock resistance requirements). This enables inline 100% inspection in harsh environments while reducing maintenance man-hours.

LS-9000 Series for Outer Diameter and Ovality Measurement of Steel Pipes and Tubes

An optical micrometer that detects edges using transmitted green LED light. With 2-axis simultaneous measurement and an environmentally resistant design, it ensures stable measurement even on harsh pipe manufacturing lines.

For Outer Diameter and Ovality Measurement of Steel Pipes and Tubes — LS-9000 Series

High-speed optical micrometer

The outer diameter of steel pipes and tubes is measured without contact using an optical method that detects edges of transmitted green LED light with a CMOS sensor. The 2-axis models (LS-9030D/LS-9006D) simultaneously measure the outer diameter in the X and Y directions, allowing ovality to be evaluated from the difference. The structure with no moving parts, using a high-brightness green LED and proprietary optics, reduces failures and the frequency of lens cleaning. The IP67 structure and air purge unit prevent dirt on the front of the head, and the die-cast body absorbs shock and temperature changes to protect the internal optical unit (meets IEC 60068-2-27 shock resistance requirements). High-speed sampling of 16,000 times per second and tilt correction ensure stable 100% inspection of moving steel pipes. A single controller supports simultaneous measurement of up to 16 channels, and up to four large-diameter heads capable of measuring up to φ120 mm can be connected.

View Catalog

Click here for LS-9000 Series product information

Get Detailed Materials for the LS-9000 Series

You can download a free catalog summarizing specifications, system configuration, and application examples.

View Catalog

Inquiries regarding outer diameter and ovality measurement of steel pipes and tubes

Application Examples of Outer Diameter and Ovality Measurement of Steel Pipes and Tubes

The LS-9000 Series is used for outer diameter and ovality measurement in various steel pipe processes, such as pipe manufacturing and rolling.

Inline Outer Diameter and Ovality Measurement on Pipe Manufacturing Lines

Steel pipes flowing continuously are measured simultaneously on the X and Y axes to monitor the outer diameter and ovality for 100% inspection. High-speed sampling of 16,000 times per second enables reliable measurement despite vibration during travel and prevents missing local changes in outer diameter.

Outer Diameter Measurement of Large-Diameter Steel Pipes

By using two sensor heads, the outer diameter of large-diameter steel pipes, such as φ500 mm, which cannot be captured by a single head, can be measured. Non-contact 100% inspection is performed even for large-sized objects that are difficult to handle.

Stable Measurement in Dust and Coolant Environments (Environmentally Resistant Design)

The IP67 structure and air purge unit prevent dirt on the front of the head, and the structure with no moving parts reduces failures of moving parts and the frequency of lens cleaning. The die-cast body absorbs shock and temperature changes to protect the internal optics (shock resistance IEC 60068-2-27). Measurement can be performed without stopping even on pipe manufacturing lines with dust or coolant.

Frequently Asked Questions Regarding Outer Diameter and Ovality Measurement of Steel Pipes and Tubes

Yes, they can. The 2-axis models (LS-9030D/LS-9006D) simultaneously acquire the outer diameter in the X and Y directions, allowing ovality (ovality of the cross section) to be evaluated from the difference.

Yes, it can. The IP67 structure and air purge unit prevent dirt on the front of the head, and the structure with no moving parts reduces failures of moving parts, ensuring stable measurement even on harsh pipe manufacturing lines.

Yes, it can. Non-contact X-Y 2-axis measurement obtains the outer diameter and ovality in a single pass. Continuous measurement can be performed over the entire length without stopping the moving steel pipe.

Yes, it can. With high-speed sampling of 16,000 times per second and non-contact measurement, it supports continuous 100% inspection on pipe production lines.

Yes, it can. The tilt correction function handles vibration and tilt during operation, and the die-cast body and optical unit protection design absorb shock and temperature changes (meets IEC 60068-2-27 shock resistance requirements).

Yes, it can. Up to four large-diameter heads capable of measuring up to φ120 mm can be connected, and a single controller supports simultaneous measurement of up to 16 channels.

  • High-speed optical micrometer LS-9000 series

High-speed optical micrometer

LS-9000 series

← All articles

What this article says

More in Industrial & Industry 4.0

All →
Controlling Can Dimensions in the Can Manufacturing Process: Outer Can Dimensions, Grooves Inside the Can, and Gaps With the Lid
Keyence

Controlling Can Dimensions in the Can Manufacturing Process: Outer Can Dimensions, Grooves Inside the Can, and Gaps With the Lid

Non-Contact Thickness Measurement of Metal Foil—Capturing the Thickness of Moving Amorphous Foil
Keyence

Non-Contact Thickness Measurement of Metal Foil—Capturing the Thickness of Moving Amorphous Foil

3D Measurement of Flatness and Warpage: 100% Inspection of Traveling Steel Sheets With Line Profiles
Keyence

3D Measurement of Flatness and Warpage: 100% Inspection of Traveling Steel Sheets With Line Profiles

3D Coplanarity Measurement: 100% Surface Judgment of Terminal Group Heights
Keyence

3D Coplanarity Measurement: 100% Surface Judgment of Terminal Group Heights

3D Measurement of PCB Warpage: 100% Surface Inspection of Mounted Component Heights
Keyence

3D Measurement of PCB Warpage: 100% Surface Inspection of Mounted Component Heights

Biodiesel Plant Improves Process Control, Increases Output | Rockwell Automation | US
Rockwell Automation

Biodiesel Plant Improves Process Control, Increases Output | Rockwell Automation | US

More from Keyence

Controlling Can Dimensions in the Can Manufacturing Process: Outer Can Dimensions, Grooves Inside the Can, and Gaps With the Lid
Keyence

Controlling Can Dimensions in the Can Manufacturing Process: Outer Can Dimensions, Grooves Inside the Can, and Gaps With the Lid

Non-Contact Thickness Measurement of Metal Foil—Capturing the Thickness of Moving Amorphous Foil
Keyence

Non-Contact Thickness Measurement of Metal Foil—Capturing the Thickness of Moving Amorphous Foil

3D Measurement of Flatness and Warpage: 100% Inspection of Traveling Steel Sheets With Line Profiles
Keyence

3D Measurement of Flatness and Warpage: 100% Inspection of Traveling Steel Sheets With Line Profiles

3D Coplanarity Measurement: 100% Surface Judgment of Terminal Group Heights
Keyence

3D Coplanarity Measurement: 100% Surface Judgment of Terminal Group Heights

3D Measurement of PCB Warpage: 100% Surface Inspection of Mounted Component Heights
Keyence

3D Measurement of PCB Warpage: 100% Surface Inspection of Mounted Component Heights

Non-Contact Measurement of Groove Depth and Width: Numerical Inspection of Groove Dimensions With 3D Shape Measurement
Keyence

Non-Contact Measurement of Groove Depth and Width: Numerical Inspection of Groove Dimensions With 3D Shape Measurement