Three Issues That Occur When Terminal Coplanarity Cannot Be Measured Correctly
The coplanarity of terminal groups directly affects mounting quality. Contact and 2D inspections each have their own limitations on-site.
Terminal Lift and Height Variation Lead to Mounting Defects
If coplanarity is lost, it causes soldering defects and contact failures. Even a single lifted terminal results in a defect for the entire product, making it important to manage the height variation of the entire terminal group. If lifted terminals are overlooked and allowed to pass, bonding failures will occur during mounting in subsequent processes, leading to reduced connection reliability and failures/complaints in the market for final products, as well as rework in subsequent processes and at set manufacturers.
Contact Methods Deform Terminals, Making 100% Inspection Difficult
Measurement with feeler gauges or microscopes is time-consuming and carries the risk of damaging fine terminals. This inevitably leads to sample-based inspection, making it impossible to manage the height variation of the entire terminal group for 100% of the products. If defective terminals missed during sampling escape to subsequent processes, post-mounting rework and repairs occur, leading to quality variation in final products, which causes a decrease in yield rate and an increase in costs.
Difficult to Capture Height and Lift as a Surface With 2D Images and Image Processing
With a camera from above, it is difficult to distinguish missing sections and height, and minute warpage or lift of the terminal group cannot be quantified as a surface. It can also be affected by surface reflections or same-color areas. If products are passed with overlooked height abnormalities, connection failures will occur during soldering in subsequent processes, manifesting as contact failures or malfunctions in final products, which may lead to failures and complaints in the market.
Coplanarity Inspection Procedure and Measurement Points
From 3D acquisition of terminal groups to 100% inspection, coplanarity and height are quantitatively measured without contact.
- 1 3D acquisition of terminal group – Step 1. The LJ-S8000 Series collectively acquires the height of the terminal group as a surface, simultaneously generating 3D and grayscale images.
- 2 Coplanarity and height judgment – Step 2. Calculate the height and lift of each terminal relative to the reference plane to quantitatively judge coplanarity.
- 3 Pitch and housing inspection – Step 3. Inspect terminal pitch, position, and housing chipping/protrusion amount all at once in the same scan.
- 4 100% inline judgment – Step 4. Perform 3D inspection during brief stoppages in the manufacturing process. Accurately measure without depending on the accuracy of the transfer equipment, preventing defective products from escaping.
Comparison of Terminal Height and Coplanarity Measurement Methods
Depending on the measurement method, there are significant differences in height/lift quantification, coplanarity evaluation, and inline suitability.
Non-contact, impact on target
LJ-S8000 Series (3D shape, non-contact)
○ Non-contact, no deformation
Contact methods (feeler gauges, microscopes)
× Risk of terminal deformation
2D images and image processing
○ Non-contact
LJ-X8000 Series (3D profiler)
○ Non-contact
Quantification of terminal group height and lift
LJ-S8000 Series (3D shape, non-contact)
○ Quantifying height over an area
Contact methods (feeler gauges, microscopes)
△ One point at a time
2D images and image processing
× No height information
LJ-X8000 Series (3D profiler)
○ Height quantification by cross-section
Evaluation of coplanarity
LJ-S8000 Series (3D shape, non-contact)
○ Batch measurement of terminal groups over an area
Contact methods (feeler gauges, microscopes)
△ Time-consuming and variation
2D images and image processing
× Difficult to capture over an area
LJ-X8000 Series (3D profiler)
△ Evaluation by a collection of lines
100% inline
LJ-S8000 Series (3D shape, non-contact)
○ 100% inspection over an area, high speed
Contact methods (feeler gauges, microscopes)
× Mainly sample inspection
2D images and image processing
△ Mainly flat surface inspection
LJ-X8000 Series (3D profiler)
○ Continuous measurement during transfer
Why Choose the LJ-S8000 Series
The LJ-S8000 Series acquires the heights of terminal groups collectively as a surface, performing non-contact, quantitative, 100% inline judgment of coplanarity and the lift of each terminal. It overcomes the limitations of contact methods, which carry the risk of deforming terminals, and 2D images, which make it difficult to capture height as a surface, allowing pitch and housing inspections to be performed together in the same scan.
LJ-S8000 Series for Terminal Height and Coplanarity Inspection
A 3D sensor using motor-driven scanning. It acquires the heights of terminal groups collectively as a surface and quantifies them without contact.
Supporting Terminal Height and Coplanarity Inspection — LJ-S8000 Series
3D Laser Snapshot Sensor
A 3D shape measuring instrument that collectively acquires the heights of connector terminal groups as a surface using motor-driven scanning. With a built-in scanning mechanism, there is no need for a stage, encoder, or lighting; simply installing it at a fixed point allows simultaneous acquisition of 3D and grayscale images. It quantifies coplanarity without contact based on the height and lift of each terminal relative to the reference plane, and also inspects terminal pitch and housing chipping/protrusion amount in the same scan. It supports inline 100% inspection with high-speed imaging as fast as 0.2 seconds, measuring independently of the movement accuracy of the equipment. High-speed cross-sectional profile measurement during transfer is handled by the LJ-X8000 Series 3D profiler.
View Catalog
Click here for product information on the LJ-S8000 Series
Get Detailed Materials on the LJ-S8000 Series
You can download a free catalog summarizing specifications, system configurations, and application examples.
View Catalog
Inquiries regarding terminal height and coplanarity inspection
Application Examples of Terminal Height and Coplanarity Inspection
It is used for inspecting the height and coplanarity of terminal groups, such as connector terminals, capacitors, and contact pins.
Coplanarity Inspection of Connector Terminals
Acquires the heights of terminal groups as a surface, performing 100% quantitative judgment of coplanarity and the lift of each terminal. This enables early detection of lifted terminals that cause soldering defects.
Terminal Height and Position Inspection of Film Capacitors
Collectively acquires the heights and positions of multiple terminals to evaluate variation. This enables 100% inspection of terminal height defects and misalignment.
Shape Inspection of Contact Pins
Inspects the shape in processes where contact pins are continuously transferred. An inline 3D profiler (LJ-X8000 Series) acquires the shape during transfer.
Frequently Asked Questions About Terminal Height and Coplanarity Inspection (LJ-S8000 Series)
Yes, it can. The LJ-S8000 Series collectively acquires the heights of terminal groups as a surface, and quantifies coplanarity based on the height and lift of each terminal relative to the reference plane.
Contact methods carry the risk of deforming terminals and are primarily used for sample inspection, but the LJ-S8000 Series can perform non-contact, 100% quantitative judgment of the entire terminal group.
While it is difficult to distinguish height and lift with imaging from an overhead camera, the LJ-S8000 Series uses 3D height information to capture minute warpage and lift of terminal groups as a surface.
Yes. Terminal pitch, position, and housing chipping/protrusion amount can also be inspected together in the same scan, allowing a single unit to handle multiple items.
Yes. By installing the sensor in the manufacturing process, 100% inspection can be performed. Because measurement is performed without depending on the movement accuracy of the equipment, terminal lift and other issues can be accurately inspected.
The LJ-X8000 Series inline 3D profiler supports high-speed measurement during transfer.
- 3D Laser Snapshot Sensor LJ-S8000 series
3D Laser Snapshot Sensor
LJ-S8000 series