Many battery can defects are caused during the can forming process prior to welding and sealing. Inline management is performed for the post-forming dimensions of the outer can, the groove dimensions on the inside of the can, and the clearance/step between the lid and the can.
View Catalog
Inquiries regarding battery can forming inspection
Three Reasons Why Dimensions Should Be Controlled in the Can Forming Process
Even for defects found during the sealing or welding processes, the cause can often be traced back to the can forming stage.
Outer Can Forming Dimensions and Circularity Lead to Sealing Defects
Outer cans that have undergone deep drawing and forming vary not only in outer diameter but also in angles and radii of curved sections. If the opening deviates from a true circle, the alignment with the sealing body or gasket will not be uniform. If local gaps remain, it leads to electrolyte leakage or moisture ingress, resulting in rejection as a defect during the sealing process. Deformation of the opening is on the scale of tens of micrometers and cannot be determined visually. Measuring at the can stage before sealing eliminates the need to stop the sealing process.
Beading and Crimping Dimensions Determine Airtightness
In cylindrical cans, the sealing body is fixed by beading (grooving) and crimping. If the depth or position of the groove or the height after crimping varies, the compression amount of the gasket changes, making it impossible to ensure airtightness. Since crimping involves plastic deformation, contact measurement may deform the shape. If the cross-sectional shape can be acquired as is without contact, both dimensions and profiles can be managed simultaneously.
Steps and Gaps Between the Lid and the Can Lead to Welding and Sealing Defects
If a step remains with the sealing body or lid placed on it, or if there is a gap on the mating surface, the weld bead will be unstable, leading to insufficient penetration or pinholes. Even if discovered after sealing, the entire can must be discarded, resulting in the loss of the internal electrodes and separators. Since steps and gaps affect quality even with a difference of tens of micrometers, measuring on the can side before entering sealing and welding can reduce rework in subsequent processes.
Three Steps of Inline Measurement in the Can Forming Process
Measurements are placed at each process where dimensions are determined, from opening forming to crimping and alignment before sealing.
- 1 Outer can dimensions after forming – Measurement ①. In addition to the outer diameter after deep drawing and forming, the angle and radius of the curved section are measured simultaneously. With a projection method using a double-sided telecentric optical system, values remain stable even if there is positional misalignment during transport.
- 2 Inner can groove (beading) and crimping dimensions – Measurement ②. The depth and position of the groove on the inside of the can and the height after crimping are calculated from the cross-sectional shape. Because it is non-contact, measurements can be taken without deforming the shape of the plastically deformed area.
- 3 Checking steps and gaps between the lid and the can – Measurement ③. Steps and gaps with the sealing body placed are measured to check the alignment before welding and sealing. Stable inspection is possible even with height differences.
Comparison of Measurement Methods in the Can Forming Process
Comparison is made based on three management items in the can forming process and three installation requirements: compatibility with glossy surfaces, 100% inspection, and recording.
① Depth and position of the groove on the inside of the can
LJ-X8000 Series
◎ Direct measurement using cross-sectional profile
Contact gauge
△ Difficult for the stylus to enter
2D vision sensor (grayscale/planar inspection)
× Cannot determine depth
Sample inspection + micrometer
× Cannot measure
② Height/shape after crimping
LJ-X8000 Series
◎ Simultaneously acquire height and cross-sectional shape
Contact gauge
× Risk of deforming the plastically deformed part
2D vision sensor (grayscale/planar inspection)
× Cannot determine height
Sample inspection + micrometer
△ 100% inspection is difficult
③ Step/gap between lid and can
LJ-X8000 Series
◎ Simultaneously measure steps and gaps with a single unit
Contact gauge
△ Gaps are difficult to measure
2D vision sensor (grayscale/planar inspection)
△ Gap only
Sample inspection + micrometer
× Cannot measure
Compatibility with glossy metal cans
LJ-X8000 Series
◎ Suppress diffuse reflection with the stray light suppression function
Contact gauge
○ Not affected by reflection
2D vision sensor (grayscale/planar inspection)
△ Requires careful setup of lighting conditions
Sample inspection + micrometer
○ Not affected
Inline 100% inspection
LJ-X8000 Series
◎ 100% inspection during transfer
Contact gauge
× Cannot keep up with tact time
2D vision sensor (grayscale/planar inspection)
○ 100% inspection is possible
Sampling + micrometer
× Based on sampling
Inspection records and traceability
LJ-X8000 Series
◎ Save and output measured values and images
Contact gauge
× Relies on manual recording
2D vision sensor (grayscale/planar inspection)
○ Image saving is possible
Sampling + micrometer
× Relies on manual recording
Why the LJ-X8000 Series Is Chosen for Can Forming Process Inspection
The LJ-X8000 Series measures the groove depth, crimping height, steps, and gaps on the inside of cans by digitizing the cross-sectional shape as it is. Because it is non-contact, it does not deform the shape of plastically deformed parts such as crimped areas. Even with glossy metal cans, the stray light suppression function ensures stability, allowing inline 100% inspection to be configured without positioning jigs.
Products for Battery Can Forming Inspection
This measuring instrument acquires the cross-sectional shape of the can as it is, and digitizes the grooves, crimps, steps, and gaps on the inside of the can.
Supporting Dimensional and Shape Management in the Can Forming Process — LJ-X8000 Series
2D/3D Laser Profiler
Ultra-high-definition measurement of 3200 points/profile represents the cross-sectional shape in detail, digitizing battery cans using indicators such as steps, widths, angles, and cross-sectional areas. Parts that may be deformed by contact methods, such as the beading groove depth or the height after crimping, can be measured without contact. Since the height image generated from height data is not affected by printing or patterns on the can surface, stable inspection is possible even for cans with text on the exterior. The stray light suppression function works against multiple reflections and diffuse reflections that occur on glossy metal cans, representing the accurate shape. The 3D position correction function automatically corrects target misalignment and tilt, eliminating the need for positioning. When combined with the automatic target detection function, inline 100% measurement and inspection can be achieved. Inspection can be configured simply by selecting from a variety of measurement tools, and it also supports the rejection of NG parts via judgment output, as well as saving images and measured values using the FTP server function.
View Catalog
Click here for product information on the LJ-X8000 Series
Obtain Detailed Materials for the LJ-X8000 Series
You can download a catalog summarizing sensor head specifications, measurement tools, and system configuration for free.
View Catalog
Inquiries regarding battery can forming inspection
Measurement Application Examples for Cylindrical Battery Cans
These methods are used to measure everything from the dimensions of the outer can after forming to the groove dimensions on the inside of the can, and the gaps and steps between the lid and the can.
Dimensional Measurement of Outer Cans After Forming
Measures various dimensions of outer cans after processing. In addition to the outer diameter, angles and radii of curved sections can also be measured simultaneously. High-speed exposure and a depth of field of up to ±20 mm enable stable inline inspection (TM-X5000 Series).
View details of the TM-X5000 Series in the catalog
Groove Dimension Inspection Inside the Can
Measures the shape of the groove in the can of a cylindrical cell. If the groove is deformed when welding the negative current collector and the lid, it can lead to defects, so 100% inspection is required (LJ-X8000 Series).
Gap Measurement Between the Lid and the Can
Measures the gap and step before welding the sealing member and the outer can. This improves the quality of the weld and reduces the risk of minute spatter entering the battery. Ultra-high-definition measurement of 3200 points/profile and a wide dynamic range from the single-shot HDR function enable stable inspection (LJ-X8000 Series).
Frequently Asked Questions About Battery Can Forming Inspection
The main measurements are the outer diameter and circularity of the opening, the depth and position of the beading groove, and the height after crimping. Checking the step and gap between the lid and the can before sealing can reduce defects in the sealing process. The outer diameter and angle of the outer can are measured with the TM-X5000 Series, and the groove, crimp, step, and gap are measured with the LJ-X8000 Series.
This page is limited to the can forming process. The goal is to stop defects caused by forming at the forming stage.
Yes, they can. Because the cross-sectional shape is acquired non-contact, there is no risk of deforming the shape as with contact types. The height after crimping and the cross-sectional profile can be managed simultaneously.
Yes, it is stable. Because the LJ-X8000 Series makes judgments based on height data, it is not affected by printing, patterns, or color differences on the can surface. The stray light suppression function works against multiple reflections and diffuse reflections that occur on glossy surfaces.
Yes, they can. Because the 3D position correction function of the LJ-X8000 Series automatically corrects for target misalignment and tilt, measurements can be made during transfer without positioning jigs. Combined with the automatic target detection function, 100% of the flowing cans can be measured one by one. The TM-X5000 Series, which measures the outer diameter of outer cans, also has a structure that is less susceptible to misalignment due to its double telecentric optical system.
Yes, it can. By continuously saving the measured values of groove dimensions and crimp heights and tracking them as trends, they can be used to determine when to replace molds. Measured values can be saved using the FTP server function.
- 2D/3D Laser Profiler LJ-X8000 series
2D/3D Laser Profiler