The hours between a batch of review comments coming in and a revised set going out mostly go to drafting. Someone redraws the duct runs after the ceiling plan moves, reclouds a sheet after the architect reissues the plan, or builds a survey drawing from a folder of site photos. An experienced engineer could describe any of these jobs in a few sentences, and then someone still has to draw it.
Nomic now drafts that work. Describe the drawing you need, or attach one to revise, and Nomic returns a native DWG, DXF, or DGN file with your layers and title block, along with a plotted PDF. This post covers what Nomic has drafted so far, from duct plans and revised sheets to survey reports, lighting control diagrams, and the schedules and calculations that go with them. Nomic returns each drawing as a draft, and you make the final call.
Three prompts, three drawings
Each of these jobs started from a medical clinic model from the National Institute of Building Sciences or the City of Seattle’s standard plans, and each prompt is written the way a project team would ask for the drawing. Each came back as a native DWG with a plotted PDF.
A duct plan drawn over the floor plan
The second floor of the clinic needed a schematic supply and return duct plan, drawn as a new sheet over the floor plan.
The prompt:
“Lay out a schematic HVAC supply and return duct plan for the second floor of this clinic as a new DWG over the floor plan. Assume two rooftop units on the roof above the corridor, with supply mains down the main corridors and branches to a ceiling diffuser in every room. Size the mains and branches with duct sizes on the drawing, label the airflow in CFM at each diffuser, and show return grilles in the corridors. Color code supply and return, add a legend, an air distribution schedule, and keyed notes, put it on a 24x36 title block, and give me the DWG and a plotted PDF.”
“Lay out a schematic HVAC supply and return duct plan for the second floor of this clinic as a new DWG over the floor plan. Assume two rooftop units on the roof above the corridor, with supply mains down the main corridors and branches to a ceiling diffuser in every room. Size the mains and branches with duct sizes on the drawing, label the airflow in CFM at each diffuser, and show return grilles in the corridors. Color code supply and return, add a legend, an air distribution schedule, and keyed notes, put it on a 24x36 title block, and give me the DWG and a plotted PDF.”
Nomic returned sheet M-102 on a 24 by 36 inch title block. Two rooftop units feed sized supply mains, with 91 ceiling diffusers across 82 rooms, each labeled with its airflow, and 18 return grilles in the corridors. Supply and return are color coded, and the sheet carries a legend, an air distribution schedule, a rooftop unit schedule, and keyed notes.
Nomic also said up front what the numbers are. The airflows are rule-of-thumb rates per square foot by room type, not a load calculation, and the rates are listed on the sheet. Nomic wrote out its other assumptions too: return air at 85 percent of supply, outside air and final unit selection left to the engineer, and rooftop unit outlines drawn as placeholders. Those are the items an engineer replaces with project values. See more on AI HVAC ductwork drafting.
A floor plan sheet revised when the architect reissues the plan
When an architect reissues a plan, every sheet drafted from the earlier issue has to catch up. For this test, we made a new issue of the clinic’s first floor plan by editing it, then gave Nomic both issues and A-101, the floor plan sheet drafted from the earlier one.
The prompt:
“The architect issued a new first floor plan. Clinic First Floor Plan.dwg is the earlier issue and Clinic First Floor Plan - new issue.dwg is the new one. Overlay the two plans and list what changed, with a link to each change. Our floor plan sheet, A-101.dwg, was drafted from the earlier floor plan. Update A-101 to match the new floor plan: revise the walls, doors, door tags, room tags, and dimensions wherever the plan changed, put a revision cloud and delta around every change, and update the revision block. Then overlay the original A-101 against your revised A-101 with the revision clouds and deltas left out, so that overlay shows only the drawing changes, with a link to each change. Give me the revised DWG and a plotted PDF, and a short list of what you changed on A-101, with a link to each cloud on the revised sheet.”
“The architect issued a new first floor plan. Clinic First Floor Plan.dwg is the earlier issue and Clinic First Floor Plan - new issue.dwg is the new one. Overlay the two plans and list what changed, with a link to each change. Our floor plan sheet, A-101.dwg, was drafted from the earlier floor plan. Update A-101 to match the new floor plan: revise the walls, doors, door tags, room tags, and dimensions wherever the plan changed, put a revision cloud and delta around every change, and update the revision block. Then overlay the original A-101 against your revised A-101 with the revision clouds and deltas left out, so that overlay shows only the drawing changes, with a link to each change. Give me the revised DWG and a plotted PDF, and a short list of what you changed on A-101, with a link to each cloud on the revised sheet.”
Nomic found 11 changes between the two issues and linked each one to its place on the overlay. A-101 Rev 1 came back as a DWG and a PDF with 12 revision clouds, each with a delta, on their own layer, and a new Rev 1 row in the revision block. The changes included a moved partition, a widened door, renamed rooms, a removed room, and a new door, with tags and dimensions updated wherever the plan changed.
The second overlay leaves out the clouds and deltas, so it shows only the drawing changes. That lets a reviewer confirm the sheet changed where the plan changed, and nowhere else.
A project-specific detail from a city standard
A city standard plan shows a typical maintenance hole. A project needs one drawn with its own structure size, depth, pipe sizes, and inverts.
The prompt:
“Using the City of Seattle Type 205a maintenance hole standard plan and the sewer and water spacing standard as references, draft a project-specific storm drain maintenance hole detail as a new DWG: 48-inch diameter structure, 9 feet rim to invert, a 12-inch inlet pipe on the north side and a 15-inch outlet on the south side with a 0.1 foot invert drop across the structure. Show a section and a plan view with dimensions, pipe sizes, inverts, and rim elevation callouts, and add notes on bedding and backfill. Match the layers and text style of the standard plan, and give me the DWG and a plotted PDF.”
“Using the City of Seattle Type 205a maintenance hole standard plan and the sewer and water spacing standard as references, draft a project-specific storm drain maintenance hole detail as a new DWG: 48-inch diameter structure, 9 feet rim to invert, a 12-inch inlet pipe on the north side and a 15-inch outlet on the south side with a 0.1 foot invert drop across the structure. Show a section and a plan view with dimensions, pipe sizes, inverts, and rim elevation callouts, and add notes on bedding and backfill. Match the layers and text style of the standard plan, and give me the DWG and a plotted PDF.”
Nomic returned detail SDMH-1 as a DWG and a plotted PDF, with Section A-A and the plan view. The inlet sits at invert elevation 91.10, the outlet at 91.00, and the rim at 100.00, nine feet above the outlet invert. A structure data table lists the elevations, and 14 notes cover bedding, backfill, and items for the engineer to verify.
One of those notes flags a conflict. The headroom from the shelf to the bottom of the cone is 5 feet 1 inch, less than the 6 foot minimum in the standard plan, and Nomic suggested a flat-top slab or an approved shallow structure. The engineer starts with a specific item to resolve.
A schematic mechanical layout from architect plans
A schematic mechanical layout is the first pass of a mechanical design: where the equipment goes, how exhaust leaves the building, and what the equipment and fan schedules say. For a new multifamily project, Nomic got the project context, the architect’s CAD floor plans, two cut sheets for candidate heat pump units, and a blank CAD sheet set up with the firm’s layers. The prompt asked for the schematic design under the state mechanical code, with web search and code search turned on, and for a PDF good enough to send along with the CAD file.
Nomic returned a layout with heat pump placement, kitchen, dryer, and toilet exhaust with airflow values, keynotes that cite the state code requirements, chimney routing, a ventilation table, and equipment and fan schedules. The run took about 20 minutes.
Built by hand, the same package takes about a day and a half to two days, and much of it is templated. The project-specific parts still need a person to touch up and review.
A survey report and equipment layout from site photos
After a site walk, a survey team drafts a floor plan annotated with the equipment found, plus a key that ties each item to its photos. For one survey, Nomic got more than 180 photos from the roof and the space, handwritten markup from an iPad, a PDF plan of the space, a CAD drawing, and the document that lists what the space is supposed to include. Nomic ran for a little over an hour while the team worked on other projects.
Nomic drafted a to-scale floor plan in CAD and placed the rooftop units, the domestic water entry, and the electrical panels from the photos and markup. Equipment in a remote room was marked as off plan instead of placed nearby. For each rooftop unit, Nomic read the name, model number, tonnage, and serial number from the photos, then ran a web search for the year of manufacture, which the photos did not show.
The report gives every item a photo key, adds an HVAC unit schedule, summarizes deficiencies, and sorts items by trade. It also notes condition, such as rusted panels, and compares the equipment found against what the document says the space includes, citing that document for each requirement so a reviewer can open the source with one click.
Before the report went out, a reviewer checked it in Nomic’s viewer with every finding cited, reworded or removed a few notes, and moved some overlapping ones. A survey report like this takes four to eight hours to draft by hand, and about an hour and a half to two hours with Nomic, including prompting, reviewing, and adjusting.
A point cloud to a dimensioned plan
A laser scan records a space precisely, and then a drafter traces it. For a point cloud survey, Nomic read the scan, summarized the space, and drafted a CAD file dimensioned to the accuracy of the scan, with the location and elevation of each element it found. Nomic reads E57, LAS, and LAZ scans and marks any edge the scanner could not see as inferred. See scan to CAD for the formats and what Nomic drafts from them.
Lighting control diagrams from a layout and a control standard
Some projects call for detailed lighting control drawings: schedules for control zones, scenes, and equipment, plus riser diagrams and emergency fixture diagrams. Nomic got a lighting layout showing the fixtures, control zones, and fixture schedule, and a 20-page PDF describing the control equipment to use and how scenes and timing should be set up. Apart from looking up cut sheets, those two inputs hold what a person needs to draw the set.
From one prompt, Nomic drew the zone, scene, and equipment schedules and the riser diagrams in CAD and PDF, working from the equipment cut sheets. Traced zone by zone, from each lighting controller to the fixtures it serves and to the emergency power inverter, the first pass was about 90 percent of the way there. Instead of correcting each error, the follow-up gave general direction, such as making sure every lighting controller in an area connects to the inverter, and four or five short prompts finished the cleanup. When a later project uses the same control standard with different fixtures, Nomic updates the diagrams from the new inputs.
The full set takes about eight to 12 hours to draft by hand. The review after drafting takes as long as it always has, so the hours saved all come out of the drafting.
Schedules and calculations that go with the drawings
Drawings travel with spreadsheets and compliance documents, and Nomic builds those from the same inputs. In each case below, Nomic got an example of the format wanted and followed it.
- Equipment schedules. From a screenshot of an example schedule, a manufacturer’s product data booklet, and the booklet page with the wanted models checked off, Nomic wrote a detailed equipment schedule with the notes and accessory sections from the booklet, and commented on how the equipment fits the project.
- Ventilation tables. From the floor plan, the mechanical plans, and a screenshot of an example table, Nomic produced an Excel ventilation table for the applicable code, with working formulas embedded.
- Heating and cooling load calculations. From floor plans and the project’s geographic location, Nomic ran a Manual J or Manual N style load calculation per ASHRAE standards, including code-required ventilation, and returned an Excel file with tabs that explain every input and output. It is a sanity check on the calculations an engineer runs in load calculation software, not a replacement for that software.
- COMcheck files. From the floor plan, the lighting plan and schedules, lighting cut sheets, and an example XML file, Nomic produced an XML file that imports into COMcheck to produce the mechanical, plumbing, and lighting reports.
- Pump sizing. With a firm’s own sizing table in Excel, a prompt, and the Revit add-in to read the size and length of the piping runs, Nomic filled in the calculation matrix, sized the pump the way the table specifies, and commented on the inputs and the sizing.
Inside Revit and AutoCAD
Much of this work happens in a model or drawing someone already has open, so the Nomic add-ins for Revit and AutoCAD put Nomic there. In Revit, Nomic finds where ductwork clashes with structural framing and fixes the clashes it can, checks duct insulation against the specification section, sets up sheets, and tags every untagged door and room. In testing, Nomic has also drawn a plumbing riser sheet in Revit from the plans. In AutoCAD, Nomic draws a revision or a matching detail in the open drawing using the drafter’s own layers and styles.
Nothing in the model or drawing changes until a person approves the change, and each approved change is a single step you can undo. Both add-ins are in enterprise preview. Read the docs for the Revit add-in and the AutoCAD add-in.
How the work gets checked
Every example above follows the same pattern. Nomic states its assumptions, such as the airflow rates on the duct plan, captures an image of the drawing after each step, and compares that image with your existing sheets. Before reporting back, Nomic reopens and audits the saved file and checks the plotted PDF. A first draft still usually needs a round of redlines, which your team marks up and gives back to Nomic to update. Your team checks each sheet as it would a drafter’s work before anything goes out, and you make the final call.
For more on drafting, read the Nomic now drafts article from Andriy or the drafting use cases, and book a demo to see it on your own projects.











