Non-Contact Measurement of Positioning Accuracy: Verifying Actual Stages and Robots

Source: Keyence•November 20, 2026 at 04:06 AM

Non-Contact Measurement of Positioning Accuracy: Verifying Actual Stages and Robots

Non-contact measurement of stage and robot positions and heights using the CL-3000 Series confocal displacement sensor. With the coaxial multi-color confocal method and long-range model, the actual position and deflection of stage top plates and moving robot parts can be externally verified from…

Three Issues That Occur When Relying Solely on Internal Feedback for Positioning Accuracy

Meeting the encoder command value does not guarantee actual machine positioning accuracy. If actual behavior is not measured externally, oversights will occur.

Internal Feedback Cannot Capture Actual Machine Deviations

Encoders and linear scales only return values on the motor shaft and scale, and cannot determine the actual misalignment or deflection of the stage top plate or target position. This leads to the oversight that actual positioning accuracy differs even if the command value is met, leaving the true performance of the equipment unknown. As a result, the equipment cannot achieve its original accuracy, leading to dimensional variations in final products and a decrease in yield rate.

Difficult to Capture Behavior During Operation (Dynamic Behavior)

Static measurement after stopping cannot evaluate dynamic positioning behavior such as vibration during acceleration/deceleration, settling time, and trajectory variation. For higher-speed and higher-acceleration equipment, settling failures and residual vibrations will be missed unless actual behavior during operation is visualized. This causes misalignment during tact time, preventing the equipment from demonstrating its original production capacity and damaging the quality and dimensional stability of final products.

High-Accuracy External Verification Is Costly and Time-Consuming

Laser interferometers are highly accurate but expensive, with a relatively large burden for installation and adjustment, making them unsuitable for multi-point or routine verification. Without an external verification method that can easily obtain the positioning and height accuracy of actual machines at multiple points, verification is postponed and problem detection is delayed. In the meantime, degradation and abnormalities progress, seriously affecting the quality of final products through equipment performance degradation and the outflow of defects.

Verification Points for Stage and Positioning Accuracy

From stage height to dynamic behavior and robot position, the positioning accuracy of actual machines is verified without contact.

  • 1 Stage height and surface accuracy – Verification 1. Coaxially and non-contactly measure the height and surface waviness of the stage top plate to determine the actual position and deflection.
  • 2 Positioning and repeatability – Verification 2. Measure the deviation of the actual position and height relative to the command position, as well as the reproducibility of repeated round trips, to evaluate the actual accuracy after settling.
  • 3 Dynamic behavior during operation – Verification 3. Trace behavior, vibration, and settling time during acceleration/deceleration with high-speed sampling to visualize dynamic positioning performance.
  • 4 Robot and multi-point evaluation – Verification 4. Simultaneously evaluate and record the height, position, and repeatability of robot moving parts and multi-axis stages through multi-point measurement.

Comparison of Positioning Accuracy Measurement Methods

Depending on the measurement method, there are significant differences in external actual machine verification, dynamic behavior, simultaneous multi-point measurement, and ease of introduction.

Non-contact/influence on target

CL-3000 Series (coaxial, non-contact, external verification)

○ Non-contact

Encoder/linear scale (internal FB)

○ Non-contact (built-in)

Laser interferometer

○ Non-contact

Contact displacement sensor (dial gauge, etc.)

× Contact required

External verification of actual machine (top plate/workpiece)

CL-3000 Series (coaxial, non-contact, external verification)

○ Actual position/deflection measured externally

Encoder/linear scale (internal FB)

× Only values on the scale

Laser interferometer

○ Possible

Contact displacement sensor (dial gauge, etc.)

△ Contact points only

Inclined surfaces, steps, and remote locations

CL-3000 Series (coaxial, non-contact, external verification)

○ Coaxial measurement is resistant to tilts and steps, allowing external measurement

Encoder/linear scale (internal FB)

△ Built-in position only

Laser interferometer

△ Requires securing the optical path

Contact displacement sensor (dial gauge, etc.)

× Close contact required

Behavior during operation (dynamic)

CL-3000 Series (coaxial, non-contact, external verification)

○ Dynamic tracking with high-speed sampling

Encoder/linear scale (internal FB)

△ Control value-based

Laser interferometer

◯ High-speed sampling

Contact displacement sensor (dial gauge, etc.)

× Static only

Simultaneous multi-point evaluation

CL-3000 Series (coaxial, non-contact, external verification)

○ Simultaneous multi-point measurement

Encoder/linear scale (internal FB)

△ Per axis

Laser interferometer

× Multi-point is large-scale

Contact displacement sensor (dial gauge, etc.)

× One point at a time

Ease of installation

CL-3000 Series (coaxial, non-contact, external verification)

○ Easy installation, suitable for daily verification

Encoder/linear scale (internal FB)

○ Built into equipment

Laser interferometer

× Expensive, high installation burden

Contact displacement sensor (dial gauge, etc.)

△ Simple but static

Role (strength)

CL-3000 Series (coaxial, non-contact, external verification)

◎ Actual machine positioning, repeatability, height

Encoder/linear scale (internal FB)

Internal FB for control

Laser interferometer

High-accuracy reference measurement

Contact displacement sensor (dial gauge, etc.)

Static displacement

Why Choose the CL-3000 Series

The CL-3000 Series uses a coaxial multi-color confocal method to measure the height, position, and deflection of stage top plates and moving parts of robots externally without contact, visualizing actual deviations that cannot be captured by internal feedback. Because it is coaxial, it is highly resistant to tilted surfaces and steps, and the wide range (long-range type) with a reference distance of 150 mm and ±35 mm allows measurement from a distance. Multiple positions can be evaluated simultaneously through multi-point measurement, making it suitable for daily multi-point verification compared to laser interferometers, which require a heavy installation burden.

CL-3000 Series Supporting Stage and Positioning Accuracy Measurement

Confocal displacement sensor. Externally verifies the positioning and height accuracy of actual stages and robots without contact.

Supporting Stage and Positioning Accuracy Measurement - CL-3000 Series

Confocal Displacement Sensor

Non-contact measurement of displacement to the target surface using a coaxial multi-color confocal method. The actual position, height, deflection, and repeatability of stage top plates and moving parts of robots can be verified externally without relying on internal feedback. Because it is coaxial, it is highly resistant to tilted surfaces and steps, and also supports measurement through holes and glass. The long-range type (CL-L150) has a wide range with a reference distance of 150 mm and ±35 mm, allowing measurement from a distance without getting close to the stage or robot. High-speed sampling captures dynamic behavior during acceleration/deceleration and settling, and multi-point measurement evaluates the four corners of the stage and multiple points on the robot simultaneously. It can be used for positioning verification of electronic, semiconductor, and FA equipment, such as measuring the height and position of mounter suction nozzles and positioning XY stages.

View Catalog

Click here for CL-3000 Series product information

Get Detailed Materials on the CL-3000 Series

You can download a free catalog summarizing specifications, system configuration, and installation examples.

View Catalog

Inquiries regarding stage and positioning accuracy measurement

Application Examples of Stage and Positioning Accuracy Measurement

Used in electronic and semiconductor manufacturing processes to verify the height and positioning of nozzles, stages, and robot hands.

Mounter Suction Nozzle Height Measurement

Coaxial, non-contact measurement of the height of the suction nozzle tip of mounting machines. This helps identify height deviations due to wear and mounting variations, helping to maintain mounting accuracy.

Verification of XY Stage Positioning

Externally evaluates the actual position relative to the commanded position and round-trip repeatability. This identifies the positioning accuracy of the actual stage, which cannot be captured by internal feedback.

Robot Hand Height Position Measurement in Vacuum

Measures the height of the hand without contact to capture changes such as slight deflection. A dedicated head enables measurement even in a vacuum environment.

Frequently Asked Questions About Stage and Positioning Accuracy Measurement (CL-3000 Series)

Yes, it can. The CL-3000 Series confocal displacement sensor captures the actual position and height displacement of the stage top plate and workpiece without contact, verifying positioning accuracy externally.

Internal feedback only returns values on the scale, and cannot determine the actual deviation or deflection of the top plate or workpiece. Measuring the actual machine externally reveals the true positioning accuracy.

Yes, they can. Because it uses a coaxial multi-color confocal method, it is highly resistant to tilted surfaces and steps, and the long-range type (CL-L150) allows measurement from a distance with a reference distance of 150 mm and a range of ±35 mm.

Yes, it can. High-speed sampling captures dynamic behavior such as vibration during acceleration/deceleration, settling time, and trajectory variation.

While interferometers are highly accurate, they are expensive and require a significant installation effort, making them suitable for stationary, high-accuracy reference measurements. The CL-3000 Series is easy to install and can measure at multiple points, making it suitable for daily multi-point positioning and height verification.

Yes, it can. Both stage height/positioning and the height/stop position of moving robot parts can be evaluated using the same non-contact displacement measurement.

  • Confocal Displacement Sensor CL-3000 series

Confocal Displacement Sensor

CL-3000 series

← All articles

What this article says

More in Industrial & Industry 4.0

All →
3D Burr Measurement on Parts: Non-Contact, 100% Inline Quantitative Inspection
Keyence

3D Burr Measurement on Parts: Non-Contact, 100% Inline Quantitative Inspection

Non-Contact Inline Inner Diameter Measurement: 100% Inspection of Through-Holes and Rings
Keyence

Non-Contact Inline Inner Diameter Measurement: 100% Inspection of Through-Holes and Rings

Non-Contact Measurement of Stroke: Real-Time Visualization of Slide Behavior During Press Operation
Keyence

Non-Contact Measurement of Stroke: Real-Time Visualization of Slide Behavior During Press Operation

Non-Contact Vibration Measurement: Capture Amplitude and Runout With a Laser Displacement Sensor
Keyence

Non-Contact Vibration Measurement: Capture Amplitude and Runout With a Laser Displacement Sensor

Code Marking & Reading Notable Risks and Countermeasures
Keyence

Code Marking & Reading Notable Risks and Countermeasures

Non-Contact Measurement of Roll Gaps: Inline Monitoring and Control Regardless of Material or Surface Condition
Keyence

Non-Contact Measurement of Roll Gaps: Inline Monitoring and Control Regardless of Material or Surface Condition

More from Keyence

3D Burr Measurement on Parts: Non-Contact, 100% Inline Quantitative Inspection
Keyence

3D Burr Measurement on Parts: Non-Contact, 100% Inline Quantitative Inspection

Non-Contact Inline Inner Diameter Measurement: 100% Inspection of Through-Holes and Rings
Keyence

Non-Contact Inline Inner Diameter Measurement: 100% Inspection of Through-Holes and Rings

Non-Contact Measurement of Stroke: Real-Time Visualization of Slide Behavior During Press Operation
Keyence

Non-Contact Measurement of Stroke: Real-Time Visualization of Slide Behavior During Press Operation

Non-Contact Vibration Measurement: Capture Amplitude and Runout With a Laser Displacement Sensor
Keyence

Non-Contact Vibration Measurement: Capture Amplitude and Runout With a Laser Displacement Sensor

Code Marking & Reading Notable Risks and Countermeasures
Keyence

Code Marking & Reading Notable Risks and Countermeasures

Non-Contact Measurement of Roll Gaps: Inline Monitoring and Control Regardless of Material or Surface Condition
Keyence

Non-Contact Measurement of Roll Gaps: Inline Monitoring and Control Regardless of Material or Surface Condition